Handyman Bangsar logoHandyman BangsarBangsar & Damansara Heights 03-3099 1973

Water Heater Installation in Bangsar: Storage and Instant

What the supply point and the pipework must offer before a bathroom water heater is fitted or exchanged, and how storage and instant heaters differ.

A hose connection being tightened beneath a storage water heater (illustration)

Why older bathrooms were built around a storage heater

It is common to find a storage heater in the older bathrooms of Bangsar, in the condominiums of the mid-1980s and the 1990s and in houses renovated since. A tank on the wall keeps water hot and sends it through a pipe in the wall to a mixer. The usual questions follow from that arrangement: the tank has begun to weep at a seam, the water no longer becomes properly hot, or a compact instant heater is being considered in its place.

The answer depends less on the heater than on what stands behind it. A heater can be no sounder than the point and the pipes it is joined to, so the assessment begins with the connections.

What the supply point must offer

A bathroom water heater needs a properly protected supply: a switch of its own, earth-leakage protection and a sound earth. A heater draws a far heavier current than a light or a fan, so the cable and the switch have to suit the rating on its label, and a point that served the old heater is not assumed to suit a new one of a higher rating.

The wiring side of a heater is electrical work, and that is a regulated trade in Malaysia. Suruhanjaya Tenaga is the body with which electrical contractors and competent persons register. You are entitled to ask who is to carry out that part and under what registration. If an additional point, a separate circuit or attention at the distribution board proves necessary, that is identified before any quote and before anything is fitted.

What the pipework must offer

A storage heater takes cold water in at one connection and sends hot water out at another, and the hot outlet needs a pipe in the wall leading to a mixer. An instant heater takes a cold feed only, heats the water as it passes, and usually delivers it through its own hose and shower head. A bathroom piped for one kind does not automatically suit the other.

Pressure matters as well. A house is commonly fed by gravity from a tank beneath its roof; the flow on an upper floor is then often gentle, more so than in a high-rise home, and some instant heaters include a pump for that reason. A rain shower head asks more of the pressure still.

A storage heater has a relief valve whose outlet must be left clear, and a full tank is heavy enough to need fixings in brick or concrete.

Connections to the water supply are regulated too; plumbing permits come from SPAN, and the same question may fairly be asked of that part.

Storage and instant heaters compared

Point of comparisonStorage heaterInstant heater
What it servesA mixer, and often a second outlet where the pipes allowUsually a single shower
Pipework requiredA cold feed and a hot pipe to the mixerA cold feed only
Where pressure is lowThe water is still hot, the flow no better than the supplyThe flow may be poor unless the heater has a pump

What to photograph before a visit

  • The whole heater, with the wall or ceiling around it.
  • The pipe connections beneath it, close up, including any valve.
  • The label on the heater, which gives its capacity and electrical rating.
  • The heater switch, and the mixer or shower the heater feeds.

Add the building and the floor, or the road if it is a house. A visit is fixed by appointment, Monday to Saturday between 9.00 am and 6.00 pm, and in a strata building at an hour the management allows.

How an exchange proceeds

Where photographs cannot show enough, an inspection is proposed first.

  1. Isolation

    Power to the heater is switched off and the water closed. A storage tank is drained before it is lifted down, so the floor beneath is covered first.

  2. Fixing

    Fresh holes are usually needed. A bathroom wall is where concealed pipes and conduits are likeliest, in a house as in a flat, so it is checked with a detector; in a strata building the by-laws forbid drilling within 300 mm of either.

  3. Connection and test

    A storage heater is filled before it is switched on. Each joint is checked for leaks, and the heater is run until hot water reaches the outlet.

What can turn it into a different job

Apart from an unsuitable supply point, the finding that most alters the work is a change of kind. Replacing a storage heater with an instant one leaves a hot pipe in the wall with nothing to feed it, and going the other way calls for a hot pipe that may not exist. Running new pipes inside a tiled wall is renovation, and needs the management's written approval in a strata building.

What moves the cost

Cost follows the kind of heater, whether the exchange is like for like, how the old one is reached, and the state of the valve and flexible connectors disturbed along the way. The quote follows the photographs, and names anything that would have to be done by others.

If the mixer the heater feeds is stiff or dripping, the page on taps, mixers and cisterns explains when a repair is practical. The same reasoning applies on the hill at Pantai Hillpark and Bukit Pantai, and in the towers of KL Sentral, where fittings put in when a building was new tend to wear out together.

Questions about water heaters

Storage water heater or instant: which suits an older apartment?

It depends on how the bathroom was piped. Where a hot pipe already runs in the wall to a mixer, a new storage heater uses what is there. An instant heater suits a bathroom with only a cold feed. Low pressure on an upper floor favours a storage heater, or an instant one with a pump.

Can a new storage heater use the fixings and pipes left by the old one?

The pipes, usually; the fixings, seldom. Inlet and outlet positions differ a little between heaters, and flexible connectors take up the difference. Bracket holes rarely line up, so fresh ones are drilled into the brick or concrete, clear of concealed pipes and conduits. If the new tank is larger or heavier than the old, say so in your message.

The heater trips the power when it is switched on. Should it be repaired or replaced?

Leave it switched off until it has been assessed. A trip shows that the protection is working, not where the fault lies: it may be within the heater, at the switch, or in the wiring between them. Tracing it is electrical work, which is regulated, so ask who is to carry out that part and under what registration.

Start with the label and the connections

The heater's label, the pipes beneath it and the switch tell most of the story. Send them with your building or street.

Phone Message on WhatsApp